GERSTEL ODP 4

Olfactory Detection Port ODP 4

For the parallel olfactory and instrumental detection as well as isolation and concentration of odor-active substances.

ODP 4

The GERSTEL OlfactoryDetectionPort ODP 4 is a GC-O-Port that allows the instrumental and olfactory detection of odor-active substances to be performed in parallel. The substances are transferred without discrimination for sniffing. During sniffing, you can record olfactory impressions and intensities in order to match them later.

GERSTEL ODP 4 installed in a gas chromatograph including accessories

Substances of olfactory interest can be isolated and enriched using the function Sniff-and-Trap. The ODP 4 can be combined with all common gas chromatography systems.

Infographic showing how the GERSTEL ODP works in conjunction with a GC-MS

Functional principle of the ODP 4

The sample is initially separated by means of gas chromatography. It is then sub-divided using a splitter and transferred to various detectors. A defined proportion of the sample is transferred for sniffing. The transfer is performed without discrimination via the heated transfer line of the ODP 4. The ODP Recorder software records olfactory intensities and spoken comments regarding the sample.

The powerful evaluation software package ODI means that comparing these with the data obtained from an instrumental detector at a later stage is a simple matter.

Sniff & Trap Function

This function enables isolation and concentration of odor active compounds of interest within a defined retention time window without the need of complex column switching systems. Thermal desorption of the trapped compounds can subsequently be performed in the GERSTEL Thermal Desorption Unit TDU2 for further analysis.

GERSTEL ODP converted for isolation and concentration on a TD tube

Sniff & Trap allows uncomplicated handling of two types of analytical procedures:


  • Collection of separated volatile compounds over a defined retention time window and re-analysis of the trapped compounds on a GC column with orthogonal polarity (off-line heartcutting) for separation of co-eluting compounds.
  • Concentration of compounds not found in the chromatogram, but detected in the ODP, over multiple GC runs. The compounds are subsequently determined in a separate GC run.

Benefits

Determining odor-active substances is simple using the ODP 4. With the help of the ODP Recorder software provided, allocating the olfactory impressions to the instrumental data is simplicity itself.


Sniffing is not the only purpose for which the ODP 4 can be used. Substances of olfactory interest from multiple GC runs can also be enriched in a sorbent tube. The ergonomic design of the ODP 4 not only helps you maintain concentration while working, but also makes working relaxing. You can sniff the substance with or without a nose cone, without burning yourself.

Variants

The ODP 4 is available with transfer lines of different lengths.

All information also for download

GERSTEL OlfactoryDetectionPort ODP 4